Electrode with the Electrodeposited Gold–Bismuth Binary System for Voltammetric Determination of Phenylephrine, Paracetamol, and Caffeine

https://doi.org/10.26907/2542-064X.2023.1.83-93

Abstract

The Au–Bi binary system electrodeposited on the surface of a glassy carbon electrode exhibits catalytic activity during the electrooxidation of phenylephrine, paracetamol, and caffeine that enhances the peak currents and decreases overvoltage in the oxidation of organic compounds. The potential difference between the peaks of oxidation on the modified electrode is 400 mV for phenylephrine and paracetamol and 300 mV for phenylephrine and caffeine, respectively. The possibility of simultaneous voltammetric determination of phenylephrine, paracetamol, and caffeine on the glassy carbon electrode modified by the Au–Bi binary system was established. The calibration curve is linear in the concentration range from 5·10–6 to 5·10–3 M. The developed method was tested in the analysis of combined drugs.

About the Authors

L. G. Shaidarova
Kazan Federal University
Russian Federation

Kazan, 420008



I. A. Chelnokova
Kazan Federal University
Russian Federation

Kazan, 420008



D. A. Koryakovtsev
Kazan Federal University
Russian Federation

Kazan, 420008



H. S. Budnikov
Kazan Federal University
Russian Federation

Kazan, 420008



References

1. Yagmur S., Ture M., Saglikoglu G., Sadikoglu M., Yilmaz S. The quantitative detection of phenylephrine in pharmaceutical preparations and spiked human urine by voltammetry. Russ. J. Electrochem., 2018, vol. 54, no. 10, pp. 741–746. doi: 10.1134/S1023193518100063.

2. Desjardins P.J., Berlin R.G. Efficacy of phenylephrine. Br. J. Clin. Pharmacol., 2007, vol. 64, no. 4, pp. 555–556. doi: 10.1111/j.1365-2125.2007.02935.x.

3. Santos A.M., Silva T.A., Vicentini F.C., Fatibello-Filho О. Flow injection analysis system with electrochemical detection for the simultaneous determination of nanomolar levels of acetaminophen and codeine. Arabian J. Chem., 2020, vol. 13, no. 1, pp. 335–345. doi: 10.1016/j.arabjc.2017.04.012.

4. Mégarbane B. Intoxication par le paracétamol: quoi de neuf? Méd. Intensive Réa., 2017, vol. 26, no. 5, pp. 383–395. doi: 10.1007/s13546-017-1300-1. (In French)

5. Glushchenko N.N., Pleteneva T.V., Popkov V.A. Farmatsevticheskaya khimiya [Pharmaceutical Chemistry]. Moscow, Akademiya, 2004. 384 p. (In Russian)

6. Andreeva E.Yu., Dmitrienko S.G., Zolotov Yu.A. Methylxanthines: Properties and determination in various objects. Russ. Chem. Rev., 2012, vol. 81, no. 5, pp. 397–414. doi: 10.1070/RC2012v081n05ABEH004220.

7. Phenylephrine (FS.2.1.0200.18). In: Gosudarstvennaya Farmakopeya Rossiiskoi Federatsii [The State Pharmacopoeia of the Russian Federation]. Vol. 3, ed. XIV. Moscow, 2018, pp. 4971–4975. (In Russian)

8. Paracetamol (FS.2.1.0154.18). In: Gosudarstvennaya Farmakopeya Rossiiskoi Federatsii [The State Pharmacopoeia of the Russian Federation]. Vol. 3, ed. XIV. Moscow, 2018, pp. 4600–4604. (In Russian)

9. Caffeine (FS.2.1.0116.18). In: Gosudarstvennaya Farmakopeya Rossiiskoi Federatsii [The State Pharmacopoeia of the Russian Federation]. Vol. 3, ed. XIV. Moscow, 2018, pp. 4158–4162. (In Russian)

10. Budnikov G.K., Maistrenko V.N., Vyaselev M.R. Osnovy sovremennogo elektrokhimicheskogo analiza [Fundamentals of Modern Electrochemical Analysis]. Moscow, Mir, Binom LZ, 2003. 592 p. (In Russian)

11. Zhou Q., Zhai H.Y., Pan Y.F. Voltammetric determination of phenylephrine hydrochloride using a multi-walled carbon nanotube-modified carbon paste electrode. R. Soc. Open Sci., 2018, vol. 5, no. 12, art. 181264. doi: 10.1098/rsos.181264.

12. Shaidarova L.G., Gedmina A.V., Chelnokova I.A., Budnikov G.K. Selective determination of paracetamol and acetylsalicylic acid on electrode modified with a mixed-valent film of ruthenium oxide-ruthenium cyanide. Russ. J. Appl. Chem., 2011, vol. 84, no. 4, pp. 620–627. doi: 10.1134/S1070427211040112.

13. Habibi B., Abazari M., Pournaghi-Azar M.H. A carbon nanotube modified electrode for determination of caffeine by differential pulse voltammetry. Chin. J. Catal., 2012, vol. 33, nos. 11–12, pp. 1783–1790. doi: 10.1016/S1872-2067(11)60438-5.

14. Shaidarova L.G., Leksina Y.A., Chelnokova I.A., Il’ina M.A., Gedmina A.V., Budnikov H.C. Dual screen-printed electrode modified by gold – palladium binary system for flow-injection amperometric determination of dopamine and ascorbic acid. Uchenye Zapiski Kazanskogo Universiteta. Seriya Estestvennye Nauki, 2018, vol. 160, no. 1, pp. 40–53. (In Russian)


Review

For citations:


Shaidarova L.G., Chelnokova I.A., Koryakovtsev D.A., Budnikov H.S. Electrode with the Electrodeposited Gold–Bismuth Binary System for Voltammetric Determination of Phenylephrine, Paracetamol, and Caffeine. Uchenye Zapiski Kazanskogo Universiteta Seriya Estestvennye Nauki. 2023;165(1):83–93. (In Russ.) https://doi.org/10.26907/2542-064X.2023.1.83-93

Views: 82


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 2542-064X (Print)
ISSN 2500-218X (Online)