Preview

Uchenye Zapiski Kazanskogo Universiteta Seriya Estestvennye Nauki

Advanced search

Selective Voltammetric Determination of Paracetamol and Acyclovir on an Electrode Modified with Reduced Graphene Oxide and Gold Particles

https://doi.org/10.26907/2542-064X.2024.3.401-413

Abstract

The electrooxidation of acyclovir (ACv) and paracetamol (PC) on a glassy carbon electrode (GCE) coated with reduced graphene oxide (GOred) and electrodeposited gold particles (Au/GOred/GCE) was studied. The separation of the oxidation peaks of PC and ACv on the Au/GOred/GCE was achieved by decreasing overvoltage. А selective and highly sensitive voltammetric method for the simultaneous determination of PC and ACv was developed. The linear dynamic range of PC and ACv was from 5×10-3 to 5×10-8 M. The proposed method was successfully applied to detect non-metabolized forms of PC and ACv in the presence of human urine.

About the Authors

L. G. Shaidarova
Kazan Federal University
Russian Federation

Kazan, 420008.


Competing Interests:

The authors declare no conflicts of interest.



A. A. Pozdnyak
Kazan Federal University
Russian Federation

Kazan, 420008.


Competing Interests:

The authors declare no conflicts of interest.



A. V. Gedmina
Kazan Federal University
Russian Federation

Kazan, 420008.


Competing Interests:

The authors declare no conflicts of interest.



H. C. Budnikov
Kazan Federal University
Russian Federation

Kazan, 420008.


Competing Interests:

The authors declare no conflicts of interest.



References

1. Fernández M., Sepúlveda J., Aránguiz T., von Plessing C. Technique validation by liquid chromatography for the determination of acyclovir in plasma. J. Chromatogr. B, 2003, vol. 791, nos. 1–2, pp. 357–363. https://doi.org/10.1016/S1570-0232(03)00252-6.

2. State Register of Medicines. URL: http://grls.rosminzdrav.ru.

3. Wei Y.-P., Yao L.-Y., Wu Y.-Y., Liu X., Peng L.-H., Tian Y.-L., Ding J.-H., Li K.-H., He Q.-G. Critical review of synthesis, toxicology and detection of acyclovir. Molecules, 2021, vol. 26, no. 21, art. 6566. https://doi.org/10.3390/molecules26216566.

4. Lotfi Z., Gholivand M.B., Shamsipur M., mirzaei M. An electrochemical sensor based on Ag nanoparticles decorated on cadmium sulfide nanowires/reduced graphene oxide for the determination of acyclovir. J. Alloys Compd., 2022, vol. 903, art. 163912. https://doi.org/10.1016/j.jallcom.2022.163912.

5. Kacirova I., Urinovska R., Sagan J. Therapeutic monitoring of serum concentrations of acyclovir and its metabolite 9-(carboxymethoxymethyl) guanine in routine clinical practice. Biomed. Pharmacother., 2022, vol. 156, art. 113852. https://doi.org/10.1016/j.biopha.2022.113852.

6. Maillard M., Gong L., Nishii R., Yang J.J., Whirl-Carrillo M., Klein T.E. PharmGKB summary: Acyclovir/ganciclovir pathway. Pharmacogenet. Genomics, 2022, vol. 32, no. 5, pp. 201–208. https://doi.org/10.1097/FPC.0000000000000474.

7. Prescott L.F. Paracetamol: Past, present, and future. Am. J. Ther., 2000, vol. 7, no. 2, pp. 143–148. https://doi.org/10.1097/00045391-200007020-00011.

8. Bosch M.E., Ruiz Sánchez A.J., Sánchez Rojas F., Bosch Ojeda C. Determination of paracetamol: Historical evolution. J. Pharm. Biomed. Anal., 2006, vol. 42, no. 3, pp. 291–321. https://doi. org/10.1016/j.jpba.2006.04.007.

9. Zobnin Yu.V. Otravlenie paratsetamolom: klinika, diagnostika i lechenie: Informatsionnometodicheskoe pis’mo dlya studentov, klinicheskih ordinatorov, vrachei-internov i prakticheskikh vrachei [Paracetamol Poisoning: Clinical Assessment, Diagnosis, and Treatment: Guidelines and Methodological Instructions for Students, Resident Physicians, Interns, and Practitioners]. Irkutsk, Irkutsk. Gos. Med. Univ., 2002. p. 36. (In Russian)

10. Adhikari B.-R., Govindhan M., Schraft H., Chen A. Simultaneous and sensitive detection of acetaminophen and valacyclovir based on two dimensional graphene nanosheets. J. Electroanal. Chem., 2016, vol. 780, pp. 241–248. https://doi.org/10.1016/j.jelechem.2016.09.023.

11. Deliagin V.M. Acute viral respiratory infections: Principles of therapy. Pediatriya. Cons. Med., 2013, no. 3, pp. 37–42. (In Russian)

12. Smekhova I.E. A comprehensive approach to in vitro evaluation of the quality of generic oral drugs. Extended Abstract of Doct. Pharm. Sci. Diss. St. Petersburg, 2013. 48 p. (In Russian)

13. Saleh G.A., Askal H.F., Refaat I.H., Abdel-aal F.A.M. Pharmacokinetic interaction study between Acyclovir and Paracetamol using HPLC-UV method. Madridge J. Anal. Sci. Instrum., 2017, vol. 2, no. 1, pp. 28–34. https://doi.org/10.18689/mjai-1000107.

14. Ghadirinataj M., Hassaninejad-Darzi S.K., Emadi H. An electrochemical nanosensor for simultaneous quantification of acetaminophen and acyclovir by ND@Dy2O3-IL/CPE. Electrochim. Acta, 2023, vol. 450, art. 142274. https://doi.org/10.1016/j.electacta.2023.142274.

15. Shaidarova L.G., Pozdnyak A.A., Gedmina A.V., Chelnokova I.A., Murdasova D.A., Budnikov G.K. Electrochemical determination of streptomycin on an electrode modified with a composite of graphene oxide and gold–nickel binary system. Russ. J. Appl. Chem., 2023, vol. 96, no. 1, pp. 27–34. https://doi.org/10.1134/S1070427223010056.

16. Jian J.-M., Fu L., Ji J., Lin L., Guo X., Ren T.-L. Electrochemically reduced graphene oxide/ gold nanoparticles composite modified screen-printed carbon electrode for effective electrocatalytic analysis of nitrite in food. Sens. Actuators, B, 2018, vol. 262, pp. 125–136. https://doi.org/10.1016/j.snb.2018.01.164.

17. Burke L.D. Scope for new applications for gold arising from the electrocatalytic behaviour of its metastable surface states. Gold Bull., 2004, vol. 37, no. 1–2, pp. 125–135. https://doi.org/10.1007/BF03215520.

18. Kondawar M.S., Shah R.R., Waghmare J.J., Shah N.D., Malusare M.K. UV spectrophotometric estimation of Paracetamol and Lornoxicam in bulk drug and tablet dosage form using multi-wavelength method. Int. J. PharmTech Res., 2011, vol. 3, no. 3, pp. 1603–1608.

19. Shetti N.P., Nayak D.S., Malode S.J., Kulkarni R.M. Nano molar detection of acyclovir, an antiviral drug at nanoclay modified carbon paste electrode. Sens. Bio-Sens. Res., 2017, vol. 14, pp. 39–46. https://doi.org/10.1016/j.sbsr.2017.04.004.

20. Kaplun M.M., Smirnov Yu.E., Mikli V., Malev V.V. Structure of cobalt hexacyanoferrate films synthesized from a complex electrolyte. Russ. J. Electrochem., 2001, vol. 37, no. 9, pp. 914–923. https://doi.org/10.1023/a:1011992109433.


Review

For citations:


Shaidarova L.G., Pozdnyak A.A., Gedmina A.V., Budnikov H.C. Selective Voltammetric Determination of Paracetamol and Acyclovir on an Electrode Modified with Reduced Graphene Oxide and Gold Particles. Uchenye Zapiski Kazanskogo Universiteta Seriya Estestvennye Nauki. 2024;166(3):401-413. (In Russ.) https://doi.org/10.26907/2542-064X.2024.3.401-413

Views: 129